Water damage to a structure can occur in many ways. Even the most solidly built and well-maintained building can be damaged by a violent force of nature, such as a flood, hurricane, tornado, or wildfire. In other situations, a water pipe may burst, and air conditioning leak, moisture intrusion, backed up septic tank or sewer line, or a sump pump may malfunction while you’re away on vacation and do serious water damage to your home and possessions. Understanding the categories of moisture/water damage is the first step in getting your home or building back to normal conditions.
Categorizing the level of contamination of water in a damaged structure is required to perform loss assessment and evaluation activities. The category of water contamination must be considered so the correct procedures can be established for processing water-damaged structures and materials
Water damage is divided into three general categories:
1) Category 1 - Clean Water
2) Category 2 - Gray Water
3) Category 3 - Black Water
However, the category of water contamination should not be identified solely by the color of the water, but by the source, contents, history and characteristics of the water.
Category 1 - Clean water originates from a source that does not pose substantial harm to humans if the clean up is performed within 24 hours of occurrence. Clean water sources may include, but are not limited to, broken water supply lines, melting ice or snow, falling rainwater, broken toilet tanks and toilet bowls that do not contain contaminants or additives. Clean water that has contact with structural surfaces and content materials may deteriorate in cleanliness as it dissolves or mixes with soils and other contaminants, and as time elapses.
Category 2 - Gray water contains a significant level of contamination and has the potential to cause discomfort or sickness if consumed by or exposed to humans. Gray water carries microorganisms and nutrients for microorganisms. Examples of gray water sources may include, but are not necessarily limited to, discharge from dishwashers or washing machines, overflows from washing machines, overflows from toilet bowls with some urine (no feces), sump pump failures, seepage due to hydrostatic pressure, broken aquariums and punctured water beds. Gray water may contain chemicals, bio-contaminants (fungal, bacterial, viral, algae) and other forms of contamination including physical hazards. Time and temperature aggravate Category 2 water contamination levels significantly. Gray water in flooded structures that remains untreated for longer those 48 hours may change to Category 3.
Category 3 - Black water contains pathogenic agents and is grossly unsanitary. Any persons with compromised immune systems, respiratory problems or allergies, or who are under 2 years of age or elderly must remain off the job site until the building is judged safe for occupancy. Black water includes sewage and other contaminated water sources entering or affecting the indoor environment. Toilet backflows that originate from beyond the toilet trap is considered black water contamination, regardless of visible content or color. Category 3 water includes all forms of flooding from seawater, ground surface water and rising water from rivers or streams. Such water sources carry silt and organic matter into structures that create black water conditions. The water is considered to be Category 3 water in situations where structural materials and/or contents have been contaminated with such contaminants as pesticides, heavy metals, or toxic substances.
Even when a building structure has recovered from water damage (cat 1 thru cat 3), it can still pose a health threat. Though everything may appear OK visually, the interstitial side of the buildings structure may be blooming with fungal propagules. Discoloration of the walls and other places are a primary indicator that mold remediation is needed. If the discoloration is in multiple places, it is of even more concern as the interstitial sides could be 10 to 100 times greater than what is visibly seen. Usually these circumstances signify there is mold growing in the house as a result of the previous damage, and this could be hazardous to the health of individuals living in the house.
A professional evaluation and laboratory analysis is needed to better ascertain the extent of the potential damage that may be lurking in your home or building. Two key options include evalu-aire a professional DIY kit available at www.indoorairtest.com to sample both the air and surfaces of the building or to hire a professional environmental consulting firm that will look both at the ambient conditions of the structure, the HVAC system, interstitial wall cavities, evaluate the structure envelope, etc… to determine the cause of potential damage and provide a specific remedy for effective removal.
Water damage can be hazardous to your health if the proper, effective identification (Cat 1-3), professional analysis and remediation are not taken into effect.
You can contact the Building Scientists at Pure Air Control Services for a professional evaluation of your building or home at 1-800-422-7873 ext 802 or for the DIY evalu-aire contact Cy Garner at 1-800-422-7873 ext 804.
About Pure Air Control Services:
Pure Air Control Services, Inc. was founded in 1984 as a small mechanical contracting firm today sets the industry standard for indoor environmental quality diagnosis and remediation.
Pure Air Control Services is a national provider of the following IAQ services: Building Sciences Evaluation; Building Health Check (USP 797 monitoring compliance); Environmental Diagnostics Laboratory (EDLab) an AIHA accredited micro laboratory (USP 797 Lab analysis); DIY IAQ Green Check test kits, Environmental Project Management; HVAC System Cleaning and Mold Remediation Services among other indoor environmental services.
The company’s expanding valued client roster includes the General Services Administration (GSA); Federal Aviation Administration (FAA), Allstate Insurance; Carrier Air Conditioning; Naval Air Warfare Center, Orlando; and Naval Air Station - King's Bay, Georgia, and many other Fortune 500 companies, school boards, and city, state, and county governments, making Pure Air Control Services the reliable industry leader in IAQ.
Pure Air Control Services, Inc. contacts:
Dr. Rajiv Sahay, Laboratory Director
1-800-422-7873 ext 301
Doug Randall, Remediation Manager
800-422-7873 ext 401
Alan Wozniak, President/CEO
800-422-7873 ext 802
This annual event provides an opportunity for licensed contractors throughout the State of Florida to obtain all 14 state-required hours of continuing education over the course of the two-day event.
Released On: 3/8/2014
Views: 4251
Although this type of bacteria was around before1976, more illness from Legionnaires' disease is being detected now. Due to consumer awareness, added research and technological advances in healthcare Legionnaires disease identification is becomi ...
Released On: 3/4/2014
Views: 4088
Performance of a building depends on its structured integrity, preventive maintenance, as well as periodical monitoring of the environmental conditions essential for its functionality.
Released On: 2/19/2014
Views: 4113
According to Building Operating Management magazine, expert Victor Yu, MD, Professor of Medicine, University of Pittsburgh; Chief, Infectious Disease Section, VA Medical Center, Pittsburgh, PA, disclosed that “Up to 70% of all buildings greater t ...
Released On: 2/18/2014
Views: 3669
Released On: 1/22/2014
Views: 3559
High efficiency coils are extremely susceptible to blockage from dust accumulation because once lodged deeply within the fins bacteria and mold may initiate growth, which not only compounds the blockage problems but also gives rise to excessive o ...
Released On: 1/8/2014
Views: 6347
Exposure to radon is the second leading cause of lung cancer after smoking. Radon is an odorless, tasteless and invisible gas produced by the decay of naturally occurring uranium in soil and water.
Released On: 1/8/2014
Views: 4012
World Health Organization (WHO Guidelines for Indoor Air Quality, 2009) concluded that the most important effect is increased prevalence of respiratory symptoms, allergies and asthma, as well as perturbation of the immunological systems
Released On: 12/31/2013
Views: 4042
The website is a true indoor environmental resource for the private and public sector including consumers, educational facilities e.g. schools, universities, along with city, county state and federal governments, healthcare and the public sector.
Released On: 12/20/2013
Views: 3067
“We are very proud to have been given the opportunity to display that we are a Doctor Trusted recipient. We will continue as always to help provide our customers with a great products and services,” stated Dr. Rajiv Sahay, environmental analytica ...
Released On: 12/11/2013
Views: 3997
IndoorAirtest.com is very proud to have a Doctor Trusted seal of approval displayed on our website, giving our customers more confidence when shopping with us.
Released On: 12/4/2013
Views: 4421
Released On: 10/2/2013
Views: 3355
The assessment of allergens in a house dust sample is an essential step for allergen-avoidance and provides information essential for allergen-reducing measures, in addition to managing the indoor environment from a health and hygiene point of view
Released On: 9/18/2013
Views: 5442
Healthcare-associated infections (HAIs) are infections that patients acquire during the course of receiving healthcare treatment for other conditions.
Released On: 7/31/2013
Views: 4479
Released On: 7/17/2013
Views: 4721
Released On: 7/11/2013
Views: 4790
Some common and frequently reported microbes of the indoor environment include, but are not limited to, viruses, bacteria, mycoplasma, mold (fungi), yeast, protozoa, etc.
Released On: 6/26/2013
Views: 5969
In indoor environments, this fungus can be transported from outside or may propagate on building materials such as cellulose rich sheet rocks, etc. and can generally be isolated from floors, carpets, mattress dust, Heating Ventilation Air Conditi ...
Released On: 6/19/2013
Views: 10517